The MT Enfora MT4000 tracker is a powerful tool for asset monitoring and management, offering SMS communication that allows real-time control. SMS commands are essential for accessing the device's functionalities, enabling everything from location tracking to alert configuration. To use these commands, it's important to be aware of some prerequisites, such as having an active SIM card and ensuring that messages are sent from a previously authorized number.

Additionally, the security of the password used in the SMS commands is crucial. We recommend that the password be strong and changed periodically to prevent unauthorized access. It is essential to follow best security practices to ensure that your information and assets are always protected.

By understanding how and when to use the SMS commands of the MT Enfora MT4000, you can maximize the efficiency of your tracker and ensure effective monitoring. For an even more simplified management experience, consider the Trackar platform, which offers a one-time payment solution to optimize your tracking.

SMS Commands

1. DNS and Port Configuration

To ensure a stable connection, it is recommended to use a domain DNS. You should configure the server as follows: use the address central.trackar.com.br on port 6216 for all server instances.

SET URL=central.trackar.com.br:6216

SET URL=central.trackar.com.br:6216

SET URL=central.trackar.com.br:6216

2. Carrier APN Configuration

It is essential that the APN, username, and password information are correctly entered, as they vary according to the carrier of the used SIM card. The following configurations are examples that should be adapted to your needs.

SET APN=ALLCOM.BR:ALLCOM:ALLCOM

SET APN=JBGPRS.ALGAR.BR:ALGAR:ALGAR

SET APN=META.COM.BR:VIVO:VIVO

SET APN=SMART.M2M.VIVO.COM.BR:VIVO:VIVO

SET APN=TRANSMEET.BR:TRANSMEET:TRANSMEET

3. Adjust Communication Time with Ignition On

The communication time while the ignition is on can be adjusted in seconds. For example, a 60-second interval is a common setting for data transmission.

SET T3 FREQ=060

4. Adjust Communication Time with Ignition Off

The time for communication with the ignition off can be configured in minutes. A typical setting is 55 minutes, which defines the transmission interval in this state.

SET HEARTBEAT=55

These settings are recommended to optimize the device's performance.

Special commands

5. Special Commands

The following commands allow you to manage and obtain information from the device efficiently.

GET NTW

GET INFO

GET PROG

GET LOCATION

SET SLEEP_MODE=1

WAKE_UP

SET IGNITION_DETECTION=0

SET ENGINEV=13200

GET IGNITION_DETECTION

SET RELAY=1

SET RELAY=0

REBOOT