How to configure the MT Topten MT05S tracker
How to configure the MT Topten MT05S tracker
Configuring the MT Topten MT05S tracker is a crucial step to ensure that you can accurately monitor and track your assets. To start the process, it is essential to correctly set the APN (Access Point Name) settings, which are vital for the device's communication with the cellular network. Additionally, configuring the DNS server is equally important, as it allows the tracker to connect to the desired monitoring platform without interruptions.
Another vital aspect to consider is the IMEI (International Mobile Equipment Identity), which uniquely identifies your device on the network. Proper registration of the IMEI is necessary to avoid connectivity issues and ensure that the tracker functions as expected. After completing these steps, it is recommended to conduct tests to verify the equipment's functionality and ensure that all settings have been applied correctly.
By following this guide, you will be able to make the most of the features of the MT Topten MT05S and ensure effective monitoring. For an even more complete experience, consider using the Trackar platform, which offers a one-time payment service for tracking and managing your devices.
SMS Commands
1. DNS and Port Configuration
To ensure the proper functioning of the tracker, it is essential to configure the DNS correctly. Use the provided domain for the servers, which are as follows: central.trackar.com.br:6216 for all three servers.
SET URL=central.trackar.com.br:6216
SET URL=central.trackar.com.br:6216
SET URL=central.trackar.com.br:6216
2. Operator APN Configuration
The APN configuration is crucial, as it varies according to the operator and the chip used. It is important to enter the correct APN, username, and password data to ensure the device's connectivity.
SET APN=ALLCOM.BR:ALLCOM:ALLCOM
SET APN=JBGPRS.ALGAR.BR:ALGAR:ALGAR
SET APN=META.COM.BR:VIVO:VIVO
SET APN=SMART.M2M.VIVO.COM.BR:VIVO:VIVO
SET APN=TRANSMEET.BR:TRANSMEET:TRANSMEET
3. Communication Interval with Ignition On
The communication time with the ignition on can be adjusted in seconds, allowing you to set the frequency of data transmission. The default value is 60 seconds.
SET T3 FREQ=060
4. Communication Interval with Ignition Off
Just like the communication interval with the ignition on, this parameter can be adjusted, but in minutes. The default is 55 minutes, which defines the transmission frequency when the vehicle is off.
SET HEARTBEAT=55
These settings are recommended for better performance of the tracker.
Special commands
5. Special Commands
These commands are used for various special functions of the device, such as ignition configuration, locking, and rebooting.
GET NTW
GET INFO
GET PROG
GET LOCATION
SET SLEEP_MODE=1
WAKE_UP
SET IGNITION_DETECTION=0
SET ENGINEV=13200
GET IGNITION_DETECTION
SET RELAY=1
SET RELAY=0
REBOOT
Own your tracking platform with a one-time payment