How to Configure the MT MT80 Tracker
How to Configure the MT MT80 Tracker
The MT MT80 tracker is an effective solution for real-time monitoring and location. To ensure that the device functions correctly, it is essential to perform the initial configuration, which involves entering data such as APN, DNS server, and IMEI. These parameters are fundamental for the tracker to connect to the network and send the necessary information to the monitoring platform.
In this introduction, we will cover the necessary steps to configure the MT MT80, allowing you to make the most of all the device's functionalities. Proper configuration not only ensures accuracy in location but also optimizes communication between the tracker and the system. Additionally, it is important to conduct tests to verify that all configurations have been applied correctly.
If you are looking for an efficient platform to manage your tracking information, consider Trackar. With a one-time payment, you will have access to an intuitive interface and advanced features for real-time monitoring. Get ready to maximize the security and management of your assets with the MT MT80!
SMS Commands
1. DNS and Port Configuration
For optimal configuration, it is recommended to use a domain DNS. You can set up to three servers with the same URL to ensure connectivity. Use the following command to configure:
SET URL=central.trackar.com.br:6216
SET URL=central.trackar.com.br:6216
SET URL=central.trackar.com.br:6216
2. Carrier APN Configuration
It is essential that the APN, username, and password settings are adjusted according to the specifications of the chip provider and the carrier. Below are the commands that can be used:
SET APN=ALLCOM.BR:ALLCOM:ALLCOM
SET APN=JBGPRS.ALGAR.BR:ALGAR:ALGAR
SET APN=META.COM.BR:VIVO:VIVO
SET APN=SMART.M2M.VIVO.COM.BR:VIVO:VIVO
SET APN=TRANSMEET.BR:TRANSMEET:TRANSMEET
3. Communication Time with Ignition On
The communication time with the ignition on can be adjusted in seconds. The default transmission interval is 60 seconds. Use the command below to set the desired time:
SET T3 FREQ=060
4. Communication Time with Ignition Off
The communication interval with the ignition off can be adjusted in minutes, with 55 minutes being the default. To change this time, use the command below:
SET HEARTBEAT=55
Special commands
5. Special Commands
Here are some special commands that can be used to manage the device:
GET NTW
GET INFO
GET PROG
GET LOCATION
SET SLEEP_MODE=1
WAKE_UP
SET IGNITION_DETECTION=0
SET ENGINEV=13200
GET IGNITION_DETECTION
SET RELAY=1
SET RELAY=0
REBOOT